Stays in your clinic.
Scans, images, and reports stay on the clinic PC. VeloraByte never receives them.
What USR does on the clinic PC, and what the doctor still decides. USR does not diagnose, prescribe, or choose a trigger. The doctor decides.
Scans, images, and reports stay on the clinic PC. VeloraByte never receives them.
Scanning, measuring, and drafting need no internet.
If USR cannot measure a value, it shows "Not measured". It never fills in a number it did not read.
Every value is shown for the doctor to check. Nothing is final until the doctor reviews it.
The ultrasound machine sends the study to the clinic PC over the clinic network. It appears in the Scan Inbox.
USR reads the measurements shown on the machine's screen, and measures the images it can.
Every value is shown for the doctor to check, with notes on what still needs review. A value USR could not read stays "Not measured".
USR writes a pelvis or early-pregnancy draft from fixed sentence templates, not free-written AI text, and points out what is missing.
The doctor checks the draft, changes what needs changing, and decides what the report says.
Readers for follicles, the uterus, the endometrium, the ovaries, the adnexa, the cervix, the myometrium, the pouch of Douglas, findings, and the yolk sac, and a reader for the measurement text on the machine's screen. They are written by hand, not trained, so each step can be explained.
Available now, as drafts
Writes the draft from fixed sentence templates and points out missing values before the doctor reviews it. Report sign-off in USR, with a tamper-evident record of every edit:
Coming later
The doctor checks the draft, changes what needs changing, and decides what the report says.
Available nowfor ListenIn testingfor voice-filled forms
Listen: speak a note and USR writes it down on the PC, offline, in English. Voice-filled forms: the doctor speaks and USR fills a web-based ANC first-visit form, once the clinic's own software is connected. The doctor checks every row before saving.
Coming later
The follicle cohort across a stimulation cycle, the trigger-size status, and a dose draft from the clinic's own written rules, with the doctor's dose kept in its own field. Vertex never chooses a dose or a trigger day. The doctor does.
Research only today. It was trained and checked on public scans from healthy volunteers, not on clinic patients. It joins USR only after it passes its own test and a check on the clinic's own scans.
Receives studies from the ultrasound machines on the clinic network, and shows each one as it arrives
Which study to open
Shows the images on the clinic PC
What the images show
Reads the measurement text on the machine's screen and measures the images it can. A value it could not read stays "Not measured", and a note says what is missing
Every measurement
Keeps patients and treatment cycles on the clinic PC
The clinic record
Drafts a pelvis report from the measurements, using fixed sentence templates
Whether the draft is right, and what the report says
Drafts an early-pregnancy report. The draft has no week and no fetal weight
Whether the draft is right, and what the report says
Writes down a spoken note on the PC, offline, in English
What the note says
Fills a web-based ANC first-visit form from the doctor's speech, once the clinic's own software is connected to USR
Every row, before saving
Signing a report in USR, with a tamper-evident record of every edit
Whether to sign
The follicle cohort, the trigger-size status, and a dose draft from the clinic's written rules
The dose and whether to trigger
Export of corrections, and trends from values already stored on the clinic PC
Which stored values to keep
A trained 3D follicle reader, research only, checked on public scans from healthy volunteers
Whether a measurement is right